Description
Overview
The Eaton Bussmann CD80 is a bolted-type BS88 low voltage fuse link from the Bussmann TSDC series, rated at 80 A and 415 V AC with an 80 kA breaking capacity. Designed to BS88 Part 2 and IEC 60269-2 standards, this Class gG fuse provides full-range overcurrent protection — from overload through to short-circuit fault levels — making it a dependable choice for general-purpose circuit protection in industrial and commercial LV installations. Its B1 BS size and centre tag single slot design ensure correct mechanical interchangeability and fit within compatible fuse holders and switchgear assemblies.
Key Features
- Class gG Full-Range Protection — provides both overload and short-circuit protection in a single fuse element, eliminating the need for supplementary back-up protection devices
- 80 kA Breaking Capacity — safely interrupts high prospective fault currents found in main distribution and feeder circuits, protecting downstream equipment from damage
- 415 V AC System Rating — directly matched to standard three-phase LV distribution voltage in India and across markets following IEC/BS standards
- BS Size B1 Body — standardised physical dimension ensures dimensional interchangeability with compatible BS88 fuse bases and holders
- Centre Tag Single Slot Termination — bolted tag connection provides a secure, low-resistance mechanical and electrical joint suited to high-current bus-bar assemblies
- CE Marked and RoHS Compliant — meets European safety and environmental directives, supporting system-level compliance for export-oriented and multinational facilities
- IEC 60269-2 Certified — independently verified performance to the international standard for low voltage fuses, backing reliable operation across rated conditions
- Bussmann TSDC Series — part of Eaton’s trusted switchgear distribution component range, with established supply chains and cross-reference documentation for panel builders and specifiers
Technical Specifications
| Specification | Value |
|---|---|
| Catalog Number | CD80 |
| Series | Bussmann TSDC |
| Fuse Type | BS88 Low Voltage Fuse Link, Bolted Type |
| BS Size | B1 |
| Tag Type | Centre Tag Single Slot |
| Amperage Rating | 80 A |
| Rated Voltage | 415 V AC |
| Voltage Range | 415 V AC System |
| Breaking Capacity | 80 kA |
| Fuse Class | Class gG |
| Standard | BS88 Part 2, IEC 60269-2 |
| Compliances | CE Marked, RoHS Compliant |
| Certifications | IEC Rated |
| Delivery Class | TSDC |
| Application | General purpose circuit protection — low voltage switchgear panels, motor control centres, distribution boards |
Applications & Selection Guide
The CD80 fuse link is designed for general-purpose overcurrent protection wherever a reliable, high breaking-capacity device is required in 415 V AC LV systems. Typical installation points include incoming and outgoing feeder ways in distribution boards, bus-bar sections of low voltage switchgear, and motor control centre incomer circuits where prospective fault currents can reach or exceed 80 kA. The bolted-tag format suits high-current assemblies where a secure, vibration-resistant connection is preferred over clip-in carriers.
Class gG fuses are specified when full-range protection — covering both sustained overloads and dead short-circuits — is required without coordinating a separate back-up fuse. When selecting the CD80, confirm that the prospective short-circuit current at the installation point does not exceed 80 kA and that the upstream supply voltage does not exceed 415 V AC. For motor circuits, verify that the fuse rating is compatible with the motor’s starting current profile; where high inrush is a concern, a gM or aM class device may be more appropriate for the motor branch while the CD80 continues to protect the feeder.
Across India, BS88 gG fuse links of this type are widely used in textile mill switchrooms in Coimbatore, automotive ancillary plant MCC rooms in Pune and Chennai, pharmaceutical manufacturing distribution boards in Ahmedabad and Hyderabad, and commercial building LV panels in metros. The IEC 60269-2 compliance makes the CD80 acceptable under BIS-aligned specifications and for projects following international electrical standards.
Why Buy from Shansen Enterprises?
- Authorized Eaton Channel Partner Coimbatore — direct access to genuine Eaton Bussmann products with full manufacturer backing
- 100% genuine products supplied with warranty — no risk of counterfeit or grey-market fuse links compromising your installation
- Pan-India delivery — orders despatched from Coimbatore to customers in Tamil Nadu, Karnataka, Andhra Pradesh, Maharashtra, Gujarat, and beyond
- WhatsApp technical support — get rapid assistance on product selection, cross-references, and BS88 fuse sizing from our team
- Bulk pricing for panel builders and EPC contractors — competitive rates on volume orders with consistent availability
Compatible Products & Accessories
- BS88 B1 Fuse Bases and Holders compatible with bolted-tag CD-series fuse links
- Eaton Bussmann BS88 fuse carriers and disconnectors for switchgear panel integration
- Other TSDC series fuse links in adjacent ampere ratings (e.g., CD63, CD100) for upstream/downstream coordination
- BS88 fuse pull-out handles and insulated fuse grips for safe withdrawal under energised conditions
- Eaton Bussmann gG fuse links in alternate BS sizes (B2, B4) for higher current tier coordination
- DIN rail-mount fuse holders and bus-bar adaptors for distribution board integration
Frequently Asked Questions
What does the Class gG designation mean for the Eaton Bussmann CD80 fuse link?
Class gG (general purpose, full-range breaking capacity) indicates that the CD80 is rated to interrupt all overcurrents from the minimum fusing current — typically around 1.6 times the rated current — up to its full 80 kA breaking capacity. This means a single fuse link handles both sustained overloads and high-level short-circuit faults, making it suitable for feeder and distribution circuits where comprehensive protection from one device is required. It is distinct from aM (motor) class fuses, which are designed only for short-circuit back-up protection in motor circuits.
Is the CD80 suitable for use in standard 415 V three-phase distribution systems in India?
Yes. The CD80 carries a rated voltage of 415 V AC, which directly matches the nominal three-phase LV supply voltage used throughout India (415 V line-to-line, 50 Hz). It is IEC 60269-2 rated and CE marked, aligning with the electrical standards referenced in Indian industrial and commercial electrical installations. Always verify that the actual prospective short-circuit current at your installation point does not exceed the 80 kA breaking capacity stated for this fuse.
What is the breaking capacity of the CD80 and why does it matter?
The CD80 has a breaking capacity of 80 kA. This is the maximum prospective fault current the fuse can safely interrupt without rupturing its body, causing an arc flash, or failing to clear the fault. In practice, installations close to large distribution transformers or with low source impedance can have prospective fault currents in the range of 25–80 kA; selecting a fuse with a breaking capacity equal to or greater than the prospective fault current at that point is a fundamental safety and compliance requirement. If your system’s prospective short-circuit current exceeds 80 kA, a higher-rated device must be specified.
What is the BS Size B1 and how does it affect fuse holder selection?
BS Size B1 is a standardised physical dimension defined in BS88 Part 2 for low voltage fuse links. The B1 designation governs the body length, diameter, and tag geometry of the fuse, ensuring that only correctly rated fuse links can be fitted into a B1-rated fuse base or holder — a key safety interlock that prevents under-rated fuses from being installed in higher-current positions. When selecting a fuse holder or base for the CD80, specify a unit rated for BS88 B1 centre-tag bolted-type fuse links. Using the correct BS size is mandatory for both safety compliance and correct mechanical assembly.
Can the CD80 be used for motor circuit protection in motor control centres?
The CD80 Class gG fuse link can be used on the incoming feeder or incomer section of a motor control centre operating at 415 V AC where full-range protection of the distribution circuit is required. For the individual motor branch circuit, however, gG fuses must be sized carefully against the motor’s full-load current and starting inrush — oversizing to pass starting current can reduce overload protection effectiveness. In many motor branch-circuit designs, an aM class fuse is preferred for short-circuit back-up with a thermal overload relay handling overload protection. Consult Shansen Enterprises’ technical team for motor circuit coordination advice specific to your application.
How do I order the Eaton Bussmann CD80 from Shansen Enterprises?
You can request a quote for the Eaton Bussmann CD80 directly from Shansen Enterprises in Coimbatore through any of the following channels: use the WhatsApp button on this page to send your requirement instantly, or email us with the catalog number CD80, the quantity required, and your delivery location anywhere in India. Our team will respond with pricing, lead time, and dispatch details. For bulk or project orders, mention your panel builder or EPC requirements so we can provide appropriate volume pricing and scheduled delivery options.