Authorized Channel Partner · GST Invoicing · Pan-India Dispatch
Try: 630FMM, 170M2697, high speed fuse, BS88, NH fuse
Eaton

Eaton Bussmann EITD16 – BS88 Low Voltage Fuse Link | 16 A 550 V AC | Class gG

Price on request

The Eaton Bussmann EITD16 is a BS88 Part 2 / IEC 60269-2 compliant, bolted-type Class gG fuse link rated at 16 A and 550 V AC, with an 80 kA breaking capacity for reliable general-purpose circuit protection. Designed for BS Size A1 with an open-slot tag type, it is suited for 415 V AC distribution systems including low voltage switchgear panels, motor control centers, and distribution boards. CE marked and RoHS compliant, this fuse link belongs to the Eaton Bussmann EIT Series and carries IEC certification for international-standard installations. Available from Shansen Enterprises, authorized Eaton channel partner in Coimbatore. Contact us for best price and delivery across India.

Get a price for this item

Message us on WhatsApp or email — we confirm stock, exact rating and send a GST-ready quote the same day.

Description

Overview

The Eaton Bussmann EITD16 is a bolted-type, low voltage BS88 fuse link from the Bussmann EIT Series, engineered to meet BS88 Part 2 and IEC 60269-2 standards. Rated 16 A at up to 550 V AC with an 80 kA breaking capacity, it delivers dependable overcurrent protection in 415 V AC systems across a wide range of industrial and commercial electrical installations. Its Class gG rating makes it suitable for full-range general-purpose protection covering both overload and short-circuit conditions.

Key Features

  • Class gG Full-Range Protection — covers overload and short-circuit faults in a single fuse link, reducing the need for additional protective devices
  • 80 kA Breaking Capacity — handles high prospective fault currents safely, suitable for robust industrial networks
  • 550 V AC Voltage Rating — compatible with standard 415 V AC systems and higher-voltage industrial supplies up to 550 V AC
  • BS88 Part 2 / IEC 60269-2 Compliance — internationally recognized standard ensuring interchangeability and performance consistency
  • Bolted-Type Construction — provides a secure, vibration-resistant connection ideal for panel and switchgear environments
  • BS Size A1 / Open Slot Tag Type — defined physical format for straightforward identification and correct holder selection
  • CE Marked and RoHS Compliant — meets European regulatory requirements for safety and restricted hazardous substances
  • IEC Rated Certification — independently verified performance for global and Indian industrial procurement standards
  • Bussmann EIT Series (Delivery Class EIT) — part of Eaton’s trusted portfolio with consistent availability and documented traceability

Technical Specifications

Specification Value
Catalog Number EITD16
Series Bussmann EIT
Product Type BS88 Low Voltage Fuse Link
Fuse Class Class gG
Amperage Rating 16 A
Rated Voltage 550 V AC
Voltage Range (System) 415 V AC
Breaking Capacity 80 kA
BS Size A1
Tag Type Open Slot
Fuse Type Bolted Type
Standard BS88 Part 2, IEC 60269-2
Compliances CE Marked, RoHS Compliant
Certifications IEC Rated
Delivery Class EIT
Application General purpose circuit protection, low voltage switchgear panels, motor control centers, distribution boards

Applications & Selection Guide

The EITD16 is well suited for general-purpose circuit protection duties in low voltage electrical systems operating at 415 V AC — the standard distribution voltage across Indian industrial and commercial facilities. Its 16 A rating and Class gG designation make it appropriate for protecting branch circuits, sub-distribution panels, and feeder circuits within motor control centers and main distribution boards where both overload and short-circuit protection is required in a single device.

When selecting this fuse link, confirm that the incumbent fuse holder or fuse base accepts BS88 Part 2, BS Size A1, bolted-type, open-slot tag geometry. The 80 kA breaking capacity exceeds the prospective short-circuit current levels found at most point-of-load positions in Indian LV installations, providing a reliable safety margin without oversizing. For motor loads, verify starting current profiles against the gG time-current characteristic curve available in Eaton’s published data.

Industries in India that commonly specify BS88 gG fuse links of this rating include textile machinery, pump and compressor manufacturing, food processing plants, pharmaceutical utilities, building automation panels, and general engineering workshops — all sectors with a strong presence in Coimbatore and the broader Tamil Nadu industrial corridor. The EITD16 is equally applicable in OEM panel-building for export markets requiring IEC 60269-2 certified components.

Why Buy from Shansen Enterprises?

  • Authorized Eaton Channel Partner in Coimbatore — supply directly from the authorized chain with full product authenticity
  • 100% genuine Eaton Bussmann products supplied with manufacturer warranty
  • Pan-India delivery — we ship to all major industrial cities and tier-2 locations across India
  • WhatsApp technical support — get spec clarification, cross-reference help, and application guidance quickly
  • Bulk and project pricing for panel builders, OEMs, EPC contractors, and electrical wholesalers

Compatible Products & Accessories

  • Eaton Bussmann BS88 Part 2 Fuse Bases and Holders — BS Size A1 bolted type
  • Eaton Bussmann EIT Series fuse links in adjacent ratings (6 A, 10 A, 20 A, 25 A, 32 A) for coordinated protection
  • Eaton Bussmann BS88 Fuse Carriers and Disconnectors for distribution board mounting
  • Eaton DIN rail fuse terminal blocks compatible with BS88 Class gG links
  • Eaton surge protective devices (SPDs) for coordinated LV panel protection
  • Eaton miniature circuit breakers (MCBs) for backup or downstream protection coordination

Frequently Asked Questions

What does Class gG mean for the EITD16 fuse link?

Class gG denotes a general-purpose, full-range fuse capable of interrupting all currents from the minimum fusing current up to the rated breaking capacity. The ‘g’ indicates full-range breaking capability and the ‘G’ indicates general application. For the EITD16, this means it protects circuits against both prolonged overloads and high-magnitude short-circuit faults up to 80 kA, making a separate supplementary fuse unnecessary in most LV distribution applications.

Is the EITD16 suitable for use in standard 415 V AC industrial systems in India?

Yes. The EITD16 carries a rated voltage of 550 V AC, which makes it fully compatible with India’s standard 415 V AC three-phase distribution systems. The higher rated voltage provides an additional safety margin and also permits use in some 480 V or 500 V AC installations. Always verify that the fuse holder, busbars, and enclosure are rated for the system voltage and fault level at the point of installation.

What fuse holder or fuse base is compatible with the EITD16?

The EITD16 requires a BS88 Part 2 compliant fuse base or holder that accepts BS Size A1, bolted-type fuse links with an open-slot tag format. Confirm the holder’s current and voltage ratings meet or exceed 16 A and 550 V AC respectively. Eaton Bussmann offers a range of matching fuse bases; Shansen Enterprises can advise on the correct holder part number for your specific panel or enclosure configuration — contact us via WhatsApp or email for assistance.

What is the breaking capacity of the EITD16, and why does it matter?

The EITD16 has a rated breaking capacity of 80 kA. This is the maximum prospective short-circuit current the fuse can safely interrupt without rupture or hazardous arc flash beyond the fuse body. In Indian LV installations, prospective fault currents at MCC incomers and distribution boards can be significant; an 80 kA rated fuse ensures the protection device itself does not become a hazard during a fault event. Always compare the available fault level at the installation point against this rating during panel design.

Does the EITD16 comply with IEC standards accepted in India?

Yes. The EITD16 complies with BS88 Part 2 and IEC 60269-2, both of which are widely accepted standards for low voltage fuse links in India. It is IEC Rated and CE Marked, and is RoHS compliant. These certifications are typically required for industrial procurement, government tenders, and export-oriented manufacturing facilities. Eaton Bussmann’s documentation package supports audit and compliance requirements for Indian panel builders and EPC contractors.

How do I order the Eaton Bussmann EITD16 from Shansen Enterprises?

You can request a quotation directly through Shansen Enterprises by clicking the WhatsApp button on this page or sending an email with the catalog number EITD16 and your required quantity. Our team will confirm availability, provide pricing, and arrange pan-India delivery to your location. For bulk orders, project requirements, or repeat procurement, ask about our volume pricing and scheduled delivery options. Shansen Enterprises is an authorized Eaton channel partner in Coimbatore, ensuring you receive 100% genuine products with full manufacturer support.

Additional information

Brand

Eaton

Series

Bussmann EIT

Amperage Rating

16 A

Voltage Rating AC

550 V

Interrupt Rating

80 kA

Fuse Class

Class gG

Fuse Type

BS88 Low Voltage Fuse Link

Fuse Size

BS Size A1

Standard

BS88 Part 2, IEC 60269-2

Application

General purpose circuit protection, low voltage switchgear panels, motor control centers, distribution boards

Fuse Indicator

None

Certifications

IEC Rated, CE Marked, RoHS Compliant