Description
Product Overview
The RR Kabel Superex-FR 6 sq mm Blue Copper House Wire is engineered for high-current applications where safety, conductivity, and durability cannot be compromised. With a conductor cross-section of 6 sq mm, this wire comfortably handles the sustained electrical loads demanded by modern appliances such as split air conditioners up to 2 ton, high-capacity storage geysers, and motors up to 3 HP. The FR (Flame Retardant) PVC insulation is specially formulated to resist the spread of flame along the cable, buying critical time during an electrical fault and significantly reducing the risk of fire propagation in concealed wiring within walls, conduits, and trunking. Rated at 1100V and manufactured in strict compliance with IS 694:2010, this wire meets every requirement set by the Bureau of Indian Standards for flexible and fixed wiring in buildings.
The 90-metre coil format is particularly suited to contractors and builders undertaking complete home wiring projects, commercial fitouts, or sub-main cabling in office buildings and industrial units. The blue colour coding of this wire follows Indian and international three-phase wiring conventions, designating it as the Phase B (second phase) conductor in three-phase systems, or as an alternate phase wire in single-phase installations. Using correctly colour-coded wires from a trusted brand like RR Kabel ensures compliance with NEC India guidelines, simplifies future maintenance and fault-finding, and promotes electrical safety throughout the life of the installation.
Technical Specifications
| Specification | Detail |
|---|---|
| Product Name | RR Kabel Superex-FR House Wire |
| Series | Superex-FR |
| Conductor Size | 6 sq mm |
| Conductor Material | Electrolytic Grade Copper |
| Number of Cores | 1 Core (Single Core) |
| Insulation Type | FR PVC (Flame Retardant PVC) |
| Voltage Rating | 1100V |
| Standard | IS 694:2010 |
| Coil Length | 90 Metres |
| Colour | Blue |
| SKU | RRKBL-FR-6SQ-BLU-90M |
Applications
- Air conditioner circuits for split and window AC units up to 2 ton capacity in residential bedrooms, living rooms, and offices
- High-capacity storage geyser wiring (15–25 litre and above) in bathrooms and utility areas requiring dedicated heavy-load circuits
- Main incoming and outgoing wiring runs from domestic and commercial distribution boards (DBs) and consumer unit panels
- Sub-main cables in commercial buildings, shopping complexes, and multi-storey residential apartments connecting floor-level DBs to main panels
- Motor wiring connections for single-phase and three-phase motors up to 3 HP in pumps, compressors, and industrial machinery
- Phase B conductor in three-phase four-wire systems for balanced load distribution in commercial and industrial electrical installations
- Dedicated circuits for large kitchen appliances including commercial ovens, induction cooking ranges, and dishwashers in hotels and restaurants
- Wiring for EV (electric vehicle) charging points and high-draw charging stations in residential garages and commercial parking facilities
Why Choose RR Kabel Superex-FR?
- ISI Certified FR Safety: The Superex-FR series carries the ISI mark under IS 694:2010, confirming that the flame retardant PVC insulation has been independently tested to resist fire propagation — a critical safety feature for concealed and conduit wiring in Indian homes and commercial buildings.
- High-Purity Electrolytic Copper: RR Kabel uses 99.97{21d06cf633e1d74c16ec73ab43c3358f6d2908066060866fd407f242af8b6688} pure electrolytic grade copper conductors, ensuring minimal resistive losses, excellent current-carrying capacity, and long service life even under continuous high-load conditions typical of AC and geyser circuits.
- Superior Insulation Integrity: The FR PVC insulation is formulated to withstand thermal stress, mechanical abrasion, and chemical exposure, maintaining dielectric strength over decades of use — reducing the risk of insulation breakdown that can cause short circuits and electrical fires.
- Trusted National Brand: RR Kabel is one of India’s most respected wire and cable manufacturers, with decades of manufacturing excellence and a nationwide network of authorised dealers, ensuring consistent product quality, traceability, and after-sales support for every coil.
Colour Code Guide
In Indian electrical wiring practice, the blue colour is designated for the Phase B conductor in a three-phase system, representing the second of the three live phases (R-Y-B colour coding: Red, Yellow, Blue). In single-phase installations, blue is also used as an alternate phase wire to distinguish dedicated circuits — for example, a separate AC circuit from a general lighting or power circuit — making identification easier during maintenance, upgrades, or fault diagnostics. Adhering to the IS 375 and NEC India colour coding conventions by using correctly coloured wires like this RR Kabel blue 6 sq mm wire is not only a best practice but is essential for the safety of electricians and end users throughout the lifetime of any installation.
About Shansen Enterprises
Shansen Enterprises is an authorised dealer of RR Kabel products, serving electricians, electrical contractors, builders, and homeowners across the region with genuine, ISI-certified RR Kabel wires and cables. As an authorised dealer — not merely a stockist — Shansen Enterprises provides sourcing assurance, product authenticity, and knowledgeable technical assistance to help you select the right wire for every application. To enquire about the RR Kabel Superex-FR 6 sq mm Blue House Wire 90 Metres, or to request a bulk quote for your project, please get in touch with our team via WhatsApp at +91 XXXXX XXXXX or send us an email — we are ready to assist with your requirements promptly.
Frequently Asked Questions
What is the current-carrying capacity of a 6 sq mm wire and which appliances is it suitable for?
A 6 sq mm copper wire can safely carry approximately 32–36 amperes under standard installation conditions as per IS 694:2010, making it well-suited for high-load circuits. Common applications include split and window air conditioners up to 2 ton, high-capacity storage geysers, sub-main distribution runs, and motor connections up to 3 HP. Always consult a licensed electrician to confirm the correct wire size based on your specific load, run length, and installation method.
What does the blue colour of this wire indicate in Indian electrical wiring?
In Indian three-phase wiring, blue denotes the Phase B conductor — the second phase in the standard R (Red), Y (Yellow), B (Blue) colour coding system used for three-phase four-wire installations as per IS 375 and NEC India guidelines. In single-phase systems, blue is commonly used as an alternate phase wire to identify dedicated circuits, such as a separate AC or geyser circuit, distinct from the standard red phase wire. Using correct colour coding ensures safety during maintenance and simplifies fault identification throughout the life of the installation.
What does FR (Flame Retardant) mean and why is it important for house wiring?
FR, or Flame Retardant, refers to a specially compounded PVC insulation that resists the spread of flame along the wire in the event of an electrical fault or overheating. Unlike standard PVC insulation, FR PVC is formulated to self-extinguish and limit fire propagation, which is critical for concealed wiring inside walls, ceilings, and conduits where a fire could otherwise spread undetected. For residential and commercial buildings in India, specifying FR-rated wire like the RR Kabel Superex-FR is strongly recommended as a fire safety measure and is aligned with IS 694:2010 safety requirements.
What is IS 694:2010 and how does it guarantee the quality of this RR Kabel wire?
IS 694:2010 is the Bureau of Indian Standards specification that governs PVC insulated cables for working voltages up to and including 1100V, covering requirements for conductor dimensions, insulation thickness, mechanical strength, and electrical performance. A wire bearing the ISI mark under IS 694:2010, like the RR Kabel Superex-FR, has been tested and certified to meet these minimum safety and performance parameters by an accredited laboratory. This certification gives electricians, contractors, and homeowners the assurance that the wire will perform reliably and safely under the declared conditions throughout its service life.
How can I enquire about or request a bulk quote for this wire from Shansen Enterprises?
Shansen Enterprises, as an authorised RR Kabel dealer, welcomes enquiries from electricians, contractors, builders, and individual homeowners for any quantity requirement. You can reach our team directly via WhatsApp at +91 XXXXX XXXXX or send us an email to discuss your project requirements, needed quantities, and delivery details. We do not operate an online checkout — all orders are processed through direct consultation to ensure you receive the correct product specifications for your specific application.