The Eaton Bussmann ESD6 is a 6 A, 550 V AC, Class gG low voltage fuse link conforming to BS88 Part 2 and IEC 60269-2. With an F2 BS size and long clip-on tag format, this fuse link is engineered for straightforward mounting in standard BS88-compatible fuse holders across switchgear panels and distribution boards. Its 80 kA breaking capacity ensures robust fault-current interruption in demanding industrial environments throughout India.
Key Features
- Class gG Rating — full-range general-purpose protection covering both overload and short-circuit conditions in a single fuse element
- High Breaking Capacity — 80 kA interrupting rating handles severe fault currents in industrial LV systems without fuse holder damage
- 550 V AC Voltage Rating — compatible with standard 415 V and higher-voltage 550 V AC distribution systems common in Indian industry
- F2 BS Size with Long Clip-On Tag — drop-in replacement for existing BS88 F2 clip-on fuse holders; no rewiring required
- CE Marked — meets European safety directives for low voltage apparatus, accepted for export and compliance-critical projects
- RoHS Compliant — manufactured without restricted hazardous substances, suitable for environmentally sensitive and government projects
- IEC Rated — independently certified to IEC 60269-2, ensuring predictable time-current characteristics and coordination with upstream/downstream protective devices
- Bussmann ESD Series — engineered for consistent performance, tight manufacturing tolerances, and long service life in continuous industrial duty
Technical Specifications
| Specification | Value |
|---|---|
| Catalog Number | ESD6 |
| Series | Bussmann ESD |
| BS Size | F2 |
| Tag Type | Long Clip On |
| Amperage Rating | 6 A |
| Rated Voltage (AC) | 550 V AC |
| Breaking Capacity | 80 kA |
| Fuse Class | Class gG |
| Standard | BS88 Part 2, IEC 60269-2 |
| Compliances | CE Marked, RoHS Compliant |
| Certifications | IEC Rated |
| Application | General purpose circuit protection, low voltage switchgear panels, motor control centres, distribution boards, industrial installations |
Applications & Selection Guide
The ESD6 is the correct choice when you need dependable general-purpose overcurrent protection at 6 A in a 550 V AC system. Its Class gG characteristic provides both overload (slow-blow) and short-circuit (fast) protection in a single unit, making it ideal for feeder circuits, branch circuits, and sub-distribution applications inside low voltage switchgear panels and motor control centres (MCCs).
In the Indian industrial context, the ESD6 sees wide deployment in textile mills, automotive component plants, pharmaceutical processing units, food and beverage facilities, and commercial building electrical panels across cities like Coimbatore, Chennai, Pune, Ahmedabad, and Hyderabad. The 550 V AC rating gives it headroom for use on higher-voltage 3-phase distribution systems common in heavy industry, while the 80 kA breaking capacity satisfies the prospective short-circuit current (PSCC) requirements of most LV distribution boards without needing current-limiting bus upgrades.
When selecting this fuse, verify that your existing fuse holder accepts the F2 BS size with a long clip-on tag. For motor branch circuits requiring back-up protection only (short-circuit without overload), consider the equivalent Class aR rated product. For higher current ratings in the same ESD series clip-on format, contact Shansen Enterprises for the full current range and matching fuse holders available for supply across India.
Why Buy from Shansen Enterprises?
- Authorized Eaton Channel Partner in Coimbatore — genuine products with full manufacturer traceability
- 100% genuine Eaton Bussmann stock supplied with warranty and documentation
- Pan-India delivery to all major industrial cities and tier-2 locations
- WhatsApp technical support for product selection, coordination studies, and replacement guidance
- Bulk pricing and priority allocation for panel builders, OEMs, and EPC contractors
Compatible Products & Accessories
- BS88 F2 Clip-On Fuse Holders (compatible Eaton Bussmann fuse bases for ESD series)
- Eaton Bussmann ESD series — other current ratings in F2 long clip-on format (e.g., ESD10, ESD16, ESD20, ESD25, ESD32)
- BS88 DIN-rail-mounted fuse carrier blocks for F2 size
- Eaton Bussmann indicator fuse links for visual blown-fuse detection in distribution boards
- Surge protection devices (SPDs) for coordinated LV panel protection
- Miniature circuit breakers (MCBs) for downstream branch circuit coordination
Frequently Asked Questions
What does the Class gG rating mean for the ESD6 fuse link?
Class gG denotes a general-purpose, full-range fuse capable of interrupting all currents from its minimum fusing current (overload region) up to its maximum rated breaking capacity of 80 kA (short-circuit region). Unlike back-up fuses (Class aR or gR), a Class gG fuse like the ESD6 provides complete protection — it will operate on sustained overloads as well as high fault currents — making it suitable for feeder and branch circuit protection without requiring a separate overload device in most applications.
Is the ESD6 compatible with all BS88 F2 fuse holders?
The ESD6 is designed for BS88 F2 size fuse holders that accept the long clip-on tag format. Before ordering, confirm that your existing fuse base or carrier is rated for F2 long clip-on fuse links and is suitable for 550 V AC service. If you are unsure about holder compatibility, contact Shansen Enterprises with your existing holder part number or a photo — our team can confirm compatibility or recommend a matched Eaton Bussmann fuse base.
Can the ESD6 be used in motor control centre (MCC) applications?
Yes. The ESD6 is explicitly listed for motor control centre applications in its application specification. For direct-on-line (DOL) motor starters, verify that the fuse rating is correctly coordinated with the motor full-load current, the contactor, and the overload relay. Class gG fuses used for motor circuit protection must be selected using IEC 60947-4-1 coordination tables to ensure Type 1 or Type 2 coordination. Shansen Enterprises can assist with fuse selection for specific motor ratings on request.
What is the breaking capacity of the Eaton Bussmann ESD6, and why does it matter?
The ESD6 has a breaking capacity of 80 kA, which is the maximum prospective short-circuit current the fuse can safely interrupt without rupturing, causing an arc flash hazard, or damaging the fuse holder. In Indian LV distribution systems, the prospective short-circuit current at the point of installation must be calculated and must not exceed 80 kA for this fuse to provide safe protection. For most industrial distribution boards and MCCs fed from standard transformers, an 80 kA rating is more than adequate and meets IS/IEC installation requirements.
Is the ESD6 RoHS compliant, and does that affect its electrical performance?
Yes, the ESD6 is fully RoHS compliant, meaning it is manufactured without lead, mercury, cadmium, hexavalent chromium, and other restricted hazardous substances listed under the RoHS Directive. RoHS compliance does not compromise electrical performance — the fuse meets all IEC 60269-2 time-current characteristic requirements. RoHS compliance is increasingly required for government tenders, export-oriented manufacturing projects, and ESG-conscious procurement in India.
How do I order the Eaton Bussmann ESD6 from Shansen Enterprises?
You can request a quote for the ESD6 directly through the WhatsApp button or the email enquiry form on this page. Please mention the catalog number ESD6, required quantity, and your delivery location anywhere in India. Shansen Enterprises is an authorized Eaton channel partner based in Coimbatore, Tamil Nadu, and supplies genuine Eaton Bussmann fuse links with fast dispatch and full documentation. Bulk orders for panel builders and contractors are welcome — contact us for volume pricing and scheduled delivery.